TRUE RMS digital multimeter in ergonomic and rubberized 2K housing, suitable for the most challenging measuring tasks in electrical engineering, industry, service and HVAC technology
Electrical engineering:
LoZ voltage measurement with low input impedance (>2k) to suppress reactive voltages
Measurement of the CP (duty cycle/amplitude) control signal of EV charging stations (wall boxes) for electric vehicles
(requires the BENNING EV 3-2 test adapter, item no. 044169 and adapter BNC - 4 mm jack, item no. 10231627)
Industry:
TRUE RMS voltage and frequency measurement for frequency converters and loads with superimposed harmonics
Measurement of the 4 mA to 20 mA current loop signal in process technology
Service:
AutoV function with automatic switching (AC/DC) and measuring range selection for fast troubleshooting
Visual and acoustic continuity test with fast response time (< 100 µs) for locating defective components, cable breaks and loose terminals
HVAC technology:
µA measuring range for measurements on flame sensors (ionization current) and measurement of the anode current (mA) of hot water boilers
Measurement of temperature and flue gas temperature in heating, ventilation and air conditioning (HVAC) systems
Functionality:
Voltage, current, resistance, continuity test, diode check, frequency, capacitance, duty cycle, temperature, memory function
AutoV function for automatic AC/DC voltage detection and measuring range selection
Low input impedance (LoZ) to suppress capacitive/inductive voltage components
Low-pass filter (HFR - High-frequency suppression) for measurements on frequency controllers (motor controls)
Display HOLD and Auto-HOLD when measured value is stable
Integrated VoltSensor for contactless signaling of phase voltages and cable breaks in cables
Measuring bus protection (optical/acoustic) in the µA/mA and A ranges with warning in case of incorrect range selection
LCD display with analog bar graph readout and backlight
- Indication range: 60000 (illuminated) + bar graph
- Accuracy: 0.03%
- Voltage AC: 10 uV - 1000 V
- Voltage DC: 10 uV - 1000 V
- Current AC: 0.01 uA - 10 A
- Current DC: 0.01 uA - 10 A
- Resistance: 0.01 Ohm - 60 MOhm
- Continuity and diode test
- Frequency (mains voltage): 0.001 Hz - 50 kHz
- Frequency (logic level): 0.001 Hz - 1 MHz
- Capacitance: 0.01 nF - 10 mF
- Duty cycle: 0.01% - 99.99%
- Temperature: -200 °C to +1090 °C
- 4 mA - 20 mA DC current loop: 0% (4 mA) - 100% (20 mA)
- VoltSensor for contactless voltage indication and cable break monitoring
- Filter function: HFR filter (1000 kHz)
- Memory function: HOLD/A-HOLD, MIN/MAX/AVG, PEAK/REL
- Automatic/manual measuring range selection, automatic power off
- Measuring method: TRUE RMS (AC, AC+DC)
- Measurement category: CAT III 1000 V, CAT IV 600 V
- Tested and approved according to: IEC/EN 61010-1 (DIN VDE 0411-1)
- Dimensions: 193 x 89 x 51 mm (with protective cover)
- Weight: 420 grams (with protective cover)
- Includes rubber protective cover with rear stand and test lead holder, bag, high-quality silicone test leads with gold-plated 2 mm and 4 mm measuring tips (screw-on), wire temperature sensor, batteries (3 x 1.5 V micro AAA/IEC LR03) and operating instructions
Properties
Indication range: 60000
Accuracy: 0.03 %
Voltage AC: 10 µV – 1000 V
Voltage DC: 10 µV – 1000 V
Current AC: 0.01 µA – 10 A
Current DC: 0.01 µA – 10 A
Resistance: 0.01 Ohm - 60 MOhm
Diode: Yes
Passage: Yes
Frequency: 0.001 Hz - 1 MHz
Capacitance: 0.01 nF - 10 mF
Temperature: -200 °C to +1090 °C
Volt sensor: Yes
Filter function: HFR filter (1000 Hz)
Memory function: HOLD/A-HOLD, MIN/MAX/AVG, PEAK/REL
Measurement method: TRUE RMS
Measurement category: CAT IV 600V/CAT III 1000V
EAN: 4014651446908